35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Three
Manufacturer/Factory, Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • 35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer
  • 35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer
  • 35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer
  • 35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer
  • 35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer
  • 35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer
Find Similar Products
  • Overview
  • Product Description
  • Main Features
  • Product Details
  • Product Parameters
  • Product Display
  • Fields of application
  • Customer Case
  • Packaging & Shipping
Overview

Basic Info.

Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001, CCC
Usage
Power Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Rated Capacity(kVA)
31500-240000
Hv
220kVA
LV
63kv 66kv69kv
Connection Symbol
Ynd11
Transport Package
According to Client′ S
Specification
As manufacturer′ s design
Trademark
HZEC
Origin
China
HS Code
8504232100
Production Capacity
25/ Quarter

Product Description

Product Description
35kV series transformers are with the following character- istics:low loss,low noise,protection against thunder and lightning,high short-circuit withstand capacity and beautiful appearance etc.It is made byadvanced assembling lines and method,with qualified and refined accessories.It enjoys four remote functions:"remote communication, remote test,remote adjustment and remote control".By remote control from a computer,the power station could be free from supervision in the office.35kV series energy- saving transformers have passed the ldentification Test by State Bureau of Machinery Industry,and State Power Corporation.35kV series transformers are mainly used in urban and rural power grids and other industrial,mining enterprises,power transmission and distribution industry
 and also agriculture projects.
35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer

 

Main Features

Low Noise: Reduces noise pollution to the environment.

Low Partial Discharge: Ensures stable and reliable transformer operation.
Low Temperature Rise: Provides strong overload capacity.
Low Loss: Optimizes energy structure.
Leakage-Free: Ensures high sealing performance of the transformer.
Maintenance-Free: Reduces customer maintenance costs.
High Impedance: Offers high short-circuit resistance, providing transformer safety.
Smart Components: Incorporates intelligent substation design technolog .

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable transformer manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations and high and low voltage complete sets of equipment.The equipment put into production and operation of the project advocates energy saving, intelligence, information and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center,with 71 utility model patents and 15 invention patents.With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC Products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa and other regions, covering more than 40 countries.
35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer

 

Product Details
35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer
35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer
35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer



Their main features include:

1. Low noise, reducing noise pollution to the environment;
2. Low partial discharge, ensuring stable and reliable operation of the transformer;
3. Low temperature rise, with strong overloading capacity;
4. Low loss, optimizing the energy structure;
5. No leakage, with high sealing performance of the transformer;
6. Maintenance-free, reducing the customer's maintenance costs;
7. High impedance, with high short-circuit resistance, enhancing the safety performance of the transformer;
8. Utilization of intelligent components, incorporating intelligent power station design technology.

Product Parameters

50-1600/35 SeriesThree-phase Double-winding Distribution Transformers with Off-circuit Tap Changer.
 


Rated capacity
(kVA)

Voltage ratio
(kV)

    

Connection
Symbo

ossva ues for S9
serialtranstomer

 

loss va ues for S10
seria transiormer

loss values for S1
serialtransomer

No-load
current

(%)

mpedance

(%)
      
       Weight

 

OutlineDimension
 

Gauge

mm
HV  LV No-load
0ss
Full-oad
0ss   
No-load
0ss
Full-oad
0ss   
No-load
0ss
Full-oad
0ss   
  Oil
 Weight  

Untanking
weight  
Total
weight 
L W H
50  35
38.5
±5%
or
±2×
2.5%
 0.4  Yyn0
Dyn11
0.21  1.21  0.19  1.15  0.17  1.15  6.5  275    740  1100  1000  1700  660 
100  0.29  2.02  0.26  1.92  0.23  1.92  1.8  350  995  1100  1150  1750  660 
125  0.34  2.38  0.31  2.26  0.27  2.26  1.7  430  1250  1100  1150  1800  660 
160  0.36  2.83  0.32  2.69  0.29  2.69  1.6  450  1405  1160  1150  1860  660 
200  0.43  3.33  0.39  3.16  0.34  3.16  1.5  495  1460  1230  1300  1950  660 
250  0.51  3.96  0.46  3.76  0.41  3.76  1.4  520  1625  1250  1300  2000  660 
315  0.61  4.77  0.55  4.53  0.49  4.53  1.4  590  1915  1400  1320  2070  820 
400  0.73  5.76  0.66  5.47  0.58  5.47  1.3  680  2175  1510  1350  2150  820 
500  0.86  6.93  0.77  6.58  0.69  6.58  1.2  760  2485  1620  1370  2240  820 
630  1.04  8.28  0.94  7.87  0.83  7.87  1.1  830  2950  1750  1390  2330  820 
800  1.23  9.9  1.11  9.41  0.98  9.41  880  3370  1900  1420  2400  820 
1000  1.44  12.15  1.3  11.54  1.15  11.54  1005  4140  2165  1450  2485  820 
1250  1.76  14.67  1.58  13.94  1.41  13.94  0.9  1160  4700  2230  1500  2600  1070 
1600  2.12  17.55  1.91  16.67  1.7  16.67  0.8  1250  5570  2250  1650  2650  1070 


630-2500/35 Series Three-phase Double-winding Distribution Transformers with Off-circuit Tap Changer

Rated capacty
(kVA)

Voltage ratio
(kV)

Connection
Symbo
loss values for S9
 serial transfomer
loss values for S10
 serial transfomer
loss values for S11
 serial transfomer

No-load
Current
(%)

mpedance
(%)

Weight
Outline Dimension
Gauge

mm
HV LV No-load
l0ss
Full-load
  loss
No-load
l0ss
Full-load
  loss
No-load
l0ss
Full-load
  loss
    Oil
weight
Untanking
weight
Total
Weigh
L W H
630  35      1.04  8.28  0.94  7.87  0.83  7.87  1.1    0.65    2.9   2100  1300  2300  820 
800  38.5  6.3    1.23  9.9  1.11  9.4  0.98  9.4    0.7    3.2   2200  1350  2350  820 
1000  ±5% 6.6  Yd11 1.44  12.15  1.3  11.54  1.15  11.54    0.85    3.5   2350  1450  2400  820 
1250  or 10    1.76  14.67  1.58  13.94  1.41  13.94  0.9  6.5  1.01    3.84   2500  1600  2450  1070 
1600  ±2× 10.5    2.12  17.55  1.91  16.67  1.7  16.67  0.8    1.2     2600  1700  2500  1070 
2000  2.5% 11    2.72  19.35  2.45  18.38  2.18  18.38  0.7    1.28     2730  1800  2600  1070 
2500        3.2  20.7  2.88  19.67  2.56  19.67  0.6    1.4     2870  1900  2700  1070 


35kVDouble-winding Distribution Transformers with Off-circuit Tap Changer


Rated capacity
(kVA)
 HV

Voltage ratio
(kV)

HVTapping Range

LV


Connection
Symbol


No-load loss
(kW)


No-load current
(%)


Full-load loss
(kW)


Impedance
(%)
3150   35

38.5
±2×2.5%



3.15
3.3

6.3

6.6
10.5

11
Yd11 3.80  0.56  24.30  7.0 
4000  4.52  0.56  28.80 
5000  5.40  0.48  33.03 
6300  6.56  0.48  36.90  7.5 
8000  YNd11 9.00  0.42  40.50 
10000  10.88  0.42  47.70 
12500  12.60  0.40  56.70  8.0 
16000  15.20  0.40  69.30 
20000  18.00  0.40  83.70 
25000  21.28  0.32  99.00 
31500  25.28  0.32  118.80 

35kV Double-winding Power Transformers with On-load Tap-changer


Rated capacity
(kVA)


Voltage ratio
(kV)


Connection
Symbol


No-load loss
(kW)


No-load current
(%)


Full-load loss
(kW)


Impedance
(%)

HV

HVTapping Range

LV
3150   35

38.5
±3×2.5% 6.3
6.6

10.5

11
Yd11 4.04  0.72  26.01  7.0 
4000  4.84  0.72  30.69 
5000  5.80  0.68  36.00 
6300  7.04  0.68  38.70  7.5 
8000 


YNd11
9.84  0.60  42.75 
10000  11.60  0.60  50.58 
12500  13.68  0.56  59.85  8.0 
16000  16.46  0.54  74.02 
20000  19.46  0.54  87.14 




 
Product Display

35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer
Service environment
1.Device types: outdoor type

2.Type of Voltage Regulation: Off-circuit or On-Ioad
3.Tapping Range: ±5 % ±2x2.5 % ±4x2.5 %
4.Frequency: 50Hz or 60Hz
5.Phases: Three or single
6.Connection Symbol: Dyn11,Yyn0 ( or as requested)
7.Short- circuit Impedance: Standard Impedance
8.Altiude is not exceeding 1000m,ambient temperature not exceeding 40OC. If it can't meet such conditions,we will modulate parameters in accordance with standard.

Fields of application

 

35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer
Customer Case

35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer

After-sales service
1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.

2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.

3.We use quality authentic materials, process and manufacture in strict compliance with ISO9001:2000 international quality management to ensure the quality of excellence and the smooth installation!
 

Packaging & Shipping

35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer35kvdouble-Winding Distribution Transformers with off-Circuit Tap Changer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier