Customization: | Available |
---|---|
Application: | Electronic, Instrument, Position Sensor, Audio, Lighting |
Type: | Current Transformer |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
1.It is oil/paper insulation structure. The main insulation is wound by high voltage cable paper, and is placed several capacitor screen of voltage division in the primary insulation, which can improve electric field distributing and decrease the consumption of insulation material, immersed in transformer oil afer desiccating under vacuum. It has advantages of stable and reliable performance of insulation,rich opcrated cxpcricnec, long service life.
2.Perfect fluidity performance of transformer oil is good for heat dissipation, it also has self recover ability for the failure of partial discharge caused by air bubble and dust.
3. There is a multi function oil drain valve on the base, which make it more convenient for oil sampling, draining.
4.The current ratio can be changed easily by adjusting connecting plate to series or parallel connection.
5. All adopted insulation parts are environmental protection materials.
6. Secondary terminal board is made of epoxy casting, the seal performance is more reliable.
7. The base uses spray painting or hot galvanizing, which gives a high degree of corrosion resistance.
8. Fasteners and nameplate are stainless steel.
Rated voltage,kV | 6 | 10 or 11 | 13.8 |
Highest voltage for equipment,kV | 7.2 | 12 | 15 or 17 |
Rated frequency,Hz | 50 or 60 | ||
Rated power frequency withstand voltage,kV | 23/30 | 30/42 | 40/55 |
Rated lightning impulse voltage,kV | 60 | 75 | 105 |
Flashover distance,mm | 105 | 135 | 195 |
Cree.distance,mm |
W1 :144 W2 :180 W3 :224 |
W1 :240 W2 :300 W3 :372 |
W1 :340 W2 :425 W3 :527 |
Mechanical load,N | 2500 | ||
Rated primary current,A | 5~2000 | ||
Rated secondary current,A | 1;2;5 | ||
Accuracy class | 0.1;0.2;0.5;0.2S;0.5S;5P;10P;PX. | ||
Rated output(recommended value),VA |
1A:10~30 VA 2A:10-30 VA 5A:15~50VA |
||
Instrument security factor FS | 5;10 | ||
Accuracy limit factors ALF | 10;15;20;25;30;40 | ||
Short-time thermal current (Maximum),kA | 100×Ipr |
1. Ambient temperature:-50ºC- +45ºC
2. Altitude:≤2000m(If above 2000m,the product will be customized according to user's request)
3. Pollution level: II, III, IV.