Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.

Product Description
The filter capacitor is composed of a core, a shell, a porcelain sheath for the wire outlet, etc. The box wall is soldered on both sides for installation, and one side is equipped with a ground bolt. The core of a capacitor consists of several components and insulating parts. In order to adapt to various voltages, the core consists of several small elements connected in parallel and then connected in series. The capacitor is equipped with discharge resistance inside, and the shell is formed and welded by stainless steel plate.
Usage:
The high-voltage filter capacitor is connected with other devices to form an AC filter, which is connected in parallel to the 50Hz or 60Hz high-voltage AC power system to provide a low impedance channel for one or more harmonic currents, reduce the harmonic level of the network, and improve the power factor of the system.
Executive standards:
GB/T 20994-2007; GB/T 20993-2012; DL/T 840-2003
Product Parameters
Item |
Unit |
Parameter |
Rated voltage |
kV |
6.6/√3, 6.9/√3, 7.2/√3, 10.5/√3, 10.5/2√3,11/√3, 11.5/√3, 11/2√3, 12/√3, 12/2√3, 11/2, 12/2,12.5/2,11,12,19,21,21/2, 22/2,23/2,24/2, 22/√3, 22/2√3, 24/√3, 24/2√3 (negotiable) |
Rated frequency |
Hz |
50, 60 |
Rated capacity |
kvar |
100,200,250,300,334,400,417,500,535,550,570,600,625,667,833kvar (negotiable) |
Loss Angle tangent value(tanδ) |
|
≤0.0003 |
Phase |
|
Single |
Insulation level |
kV |
42/75, 50/125 |
Discharge resistance |
|
The capacitor is equipped with discharge resistance, and after disconnecting from the grid, the voltage on the terminal can be reduced to less than 75V within 10 minutes |
Capacitance deviation |
|
-3%~+5% |
Protection method |
|
Inner fuse or No fuse |
Properties
1. Bushing: cold-pressed, anti-pollution type bushing, creepage distance is not less than 31mm/kV.
2. Mature internal fuse technology.
2.1 After the test, the internal fuse can isolate the faulty component within 0.2ms, the energy release at the fault point is not greater than 0.3kJ, and the remaining intact components are not affected.
2.2 Advanced hidden internal fuse structure, using oil gap arc extinguishing, reduce the possibility of capacitor case bursting.
2.3 Internal fuse protection and relay protection have perfect coordination standards to ensure the safe and reliable operation of the entire device.
3. Liquid medium: 100% benzyl toluene (M/DBT) is used, which has excellent low temperature performance and partial discharge performance.
4. The main insulation adopts composite insulation structure, which ensures excellent electrical performance and has certain mechanical strength, ensuring that the ground insulation of the capacitor complete set is 100% reliable without protection.
5. Good sealing performance: annual leakage rate is less than 0.1%, through automatic argon arc welding, vacuum leakage test, hot aging and other measures to ensure the sealing performance of the capacitor.
6. Partial discharge level: the extinguishing voltage is not less than 1.5Un, and each capacitor is tested for partial discharge during factory test.
Service Environment
1.Indoor and outdoor installation
2. The elevation of the installation site is generally not more than 2000 meters
3. Temperature category: -40/B, pollution level: 1V
4. There is no gas or steam that is seriously corrosive to metal
5. No strong mechanical vibration
6. No explosive, inflammable and dangerous goods.
Order Instruction
1. Rated voltage; 2. Rated capacity; 3. Rated frequency; 4. Standards,
5. Service conditions (altitude, temperature, indoor or outdoor, humidity, etc.), 6. Other special requirements.