Customization: | Available |
---|---|
Certification: | ISO9001, CCC |
Protection: | Flameproof |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameter | ||
Rated capacity | 4(KVA) | 6(KVA) |
Rated voltage (V) | 1140, 660, 380/127 | 1140, 660, 380/127 |
Rated current (A) | 2.02, 3.49, 5.8/17.36 | 3.04, 5.25, 9.12/26 |
Wiring mode | Y | |
Allowable temperature | 85K | |
Working conditions | ||
Altitude | ≤2000m | |
Ambient temperature | -20ºC~+40ºC | |
Relative humidity of the air | No more than 95% (+2%) | |
In the place where there is no strong turbulence and vibration and the vertical inclination is not more than 15 degrees; | ||
In the environment without gas and steam that can corrode metal and damage insulation; | ||
It can be used in mines with coal dust and gas hazards |
Trolley Structure
The vacuum contactor is adopted and installed on the trolley mechanism with patented technology with reversing switch, current transformer, transformer and other components. The protector and control circuit components are installed on the front door control panel. The strong and weak circuits are seperated. The components and trolley are highly interchangeable, which is convenient for installation and maintenance.
Intelligent Protection:
The advanced microcomputer intelligent protector is adopted, which has mutiple protection and electric metering functions such as overload short circuit, leakage lockout, undervoltage, overvoltage, three-phase imbalance, gas locking, wind power locking,etc.
Color Display:
Full-Chinese LCD color display screen, dynamic startup screen, which can monitor and display the current circuit voltage, three-phase curent, fault type, parameter and time in real time, and have faut memory ang query function.
Four Remote Function:
The parameter setting can be set locally by pressing the button on the side of the main switch and each branch switch screen, or through the centralized control button on the side of the centralized control panel, or can be set remotely by RS-485 interface, or Ethernet optical fiber (optional) and communication with the upper computer of the monitoring system. The remote star and stop can realize the "four remote" function to achieve unattended substation.
Quick-opening mechanism:
The shell adopts the patented screw door opening mechanism, and is equipped with reliable mechanical interlocking, electrical locking, manual tripping and other devices.
Safety Module:
The external control circuit adopts intrinsically safe and safe module, which is more safe and reliable.
Explosion-proof grade:
Explosion-proof type: Exd I Mb Protection grade: IP54