Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Manufacturer/Factory, Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
  • Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
  • Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
  • Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
  • Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
  • Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Product Parameters
  • Service Environment
  • Outline Diagram Examples
  • Factory Show
  • FAQ
  • Certifications
Overview

Basic Info.

Model NO.
FZW32-24
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
Lbs
Poles Number
3
Type
Fzw32-12
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
CCC
Customization
Acceptable
Currency
RMB or USD
Language
Chinese, English, Russian
Loading Port
It Depends
Frequency
50Hz
Rated Voltage
12kv
Rated Current
630A
Mechanism Type
Manual
Operating Environment
Outdoor
Transport Package
Standarded Export Case
Specification
As required
Trademark
HZEC
Origin
China
Production Capacity
3000 Sets/Month

Product Description

Company Profile

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
Product Description
FZW32-24KV/630A/1250A-20KA outdoor high voltage isolated vacuum load switch after strict type test and long-term trial operation assessment, all the technical performance indicators have reached GB3804 and IEC standards, suitable for rated voltage 24KV, rated current 630A, three-phase AC 50Hz power supply network.
Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
Product Parameters
No. Item Unit Parameter
1 Rated voltage KV 24
2 Rated current HZ 50
3 Rated frequency A 630/1250
4 Rated active load breaking current A 630/1250
5 Rated close-loop breaking current A 630/1250
6 5% rated active load breaking current A 20/31.5
7 Rated cable charging breaking current A 10
8 Rated no-oad transformer breaking capacity   1600
9 Rated breaking capacitor current A 100
10 1 min power frequency withstand voltage;Phase to distance, grounding to grounding;isolating fracture KV 52/65
11 Lightning impulse withstand voltage;Phase to distance, grounding to grounding; isolating fracture KV 125/145
12 Rated short-time withstand current (thermal stable) KA 20
13 Lasting time of rated short-time withstand current S 4
14 Rated peak withstand current (dynamic stable) KA 50
15 Rated short-circuit opening closing current KA 50
16 Mechanical life Time 10000
17 Allowable wear thickness of vacuum arc extinguishing contact mm 1
18 Manual operating moment N.m ≤200
19 Vacuum interrupter assembly adjustment:Contact opening distance mm 10±0.5
                                  Average opening speed m/s 1.5±0.2
                                               Three-phase opeing asynchronism ms <5
                                               Three-phase closing asynchronism ms <5
                                                Distance between charged bodies and phase to ground mm >300
                              Auxiliary loop resistance ≤150
Service Environment

1. Altitude: ≤1000m;
2. Ambient temperature: -25ºC~+40ºC;
3. Relative humidity: the daily average is not more than 95%, the monthly average is not more than 90%;
4. No conductive dust, corrosive gases and water vapor;
5. No fire and explosive risk;
6. The earthquake magnitude is no more than grade 8;
7. Pollution grade: II. 

Outline Diagram Examples
Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
Factory Show
Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
 
FAQ

Q: Could I have prices of your products?
A: Welcome. Please feel free to send us inquiry here. We will reply you within 24 hours.

Q: Can we print our logo/ company name on products?
A: Yes, of course, we accept OEM, then need you to provide brand authorization to us.

Q:Do you accept product customization?
A:Yes, of course, please provide specific drawings or parameters, we will quote you after evaluation.

Q: What is the lead time? 
A: The lead time depends on the quantities ordered, generally within 7-20 days after receiving the payment. 

Q: What is your Trade Terms? 
A: We accept EXW, FOB, CIF, FCA, etc. 

Q: Do you inspect the finished products?
A: Yes, each step of production and finished products will be came out inspection by QC department before shipping. And we will provide goods inspection reports for your reference before shipment

Q: How to solve the quality problems after sales? 
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days.

Certifications
 
Outdoor Vacuum Isolation Medium 24kv High Voltage Load Break Switch
 
 
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier