Customization: | Available |
---|---|
Application: | Power, Electronic, Instrument, Lighting, Audio, Ore |
Phase: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable transformer manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations and high and low voltage complete sets of equipment.The equipment put into production and operation of the project advocates energy saving, intelligence, information and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center,with 71 utility model patents and 15 invention patents.With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa and other regions, covering more than 40 countries.
1. It meets or exceeds ANSI.IEC.GB.SANS standards.
2. Vacuum filtration oil injection process, fully sealed structure; not susceptible to moisture, prolong service life, maintenance-free operation;
3. Compact design, low noise;
4. Corrugated oil tank, small in size and beautiful in appearance.
D14-M-(10/160)/ 10 Single Phase Oil-Immersed distribution Transformer
Rated capacity (kVA) | High Voltage (kV) | Tap range | Low voltage (kV) | Connected group label | No-load loass(W) | Load loss (75ºC)(W) | No-load current(%) |
10 | 6 6.3 6.6 10 10.5 11 |
±2*2.5 ±5 |
2*(0.22-0.24) or 0.22-0.24 | li0 li6 |
36 | 212 | 1.1 |
16 | 44 | 297 | 1.0 | ||||
20 | 52 | 346 | 0.9 | ||||
30 | 64 | 504 | 0.8 | ||||
40 | 80 | 630 | 0.8 | ||||
50 | 96 | 769 | 0.7 | ||||
63 | 116 | 918 | 0.6 | ||||
80 | 128 | 1130 | 0.6 | ||||
100 | 152 | 1340 | 0.6 | ||||
125 | 184 | 1580 | 0.5 | ||||
160 | 232 | 1920 | 0.5 |
Temperature conditions: oil-immersed transformer under the specified cooling conditions, can be operated according to the nameplate, but the top oil temperature shall not exceed 90 ° C.
In order to prevent transformer insulation aging, the top oil temperature should not often exceed 85 ° C, and the alarm setting value is set at 80 ° C.
Altitude: Usually applicable to areas with an altitude of no more than 1000 meters.
Relative humidity: When the ambient temperature is 25 ° C, the relative humidity does not exceed 90%.