Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Three
Manufacturer/Factory, Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
  • Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
  • Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
  • Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
  • Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
  • Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
Find Similar Products
  • Overview
  • Product Description
  • production process
  • Detailed Photos
  • Product Parameters
  • After Sales Service
  • Packaging & Shipping
  • Certifications
Overview

Basic Info.

Cooling Method
Dry-type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001, CCC
Usage
Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Frequency
50/60Hz
Material
Material
Tapping Method
on Load / off Load Tapping Changer
Connection Group
D, Yn11 or Y, Yn0
Warranty
3year
Logo
Qinghao or Customized
Transport Package
Wooden Box
Specification
As per data sheet
Trademark
HZEC
Origin
China
HS Code
8504220000
Production Capacity
10000PCS/Year

Product Description


 
Product Description

SCB15 Series Amorphous Alloy Transformers
       have the advantages of low no-load loss, no oil, self-extinguishing, moisture resistance, crack resistance, and maintenance-free operation. They can replace ordinary dry-type transformers in any application and are suitable for high-rise buildings, commercial centers, airports, oil platforms, maps, tunnels, airports, stations, industrial and mining enterprises, and power plants. They are particularly suitable for installation in places with high fire protection requirements, such as flammable and explosive environments.

Main Features

  1. Small size, light weight;
  2. Safe, reliable, non-polluting, can be directly operated at the load center;
  3. High mechanical strength, strong short-circuit resistance, low partial discharge, good thermal stability, high reliability, long service life;
  4. Low no-load loss, high efficiency, low noise, significant energy-saving effect;
  5. Good heat dissipation performance, strong operational capability, and capacity can be increased during forced air cooling;
  6. Good moisture resistance, suitable for operation in high humidity and other harsh environments;
  7. Environmental protection, flame retardant, explosion-proof, maintenance-free;
  8. For products with a capacity of 200KVA and above, the low-voltage winding is made of copper foil, the high-voltage winding is made of 180°C high-strength enameled wire, and the epoxy resin casting structure is adopted, providing excellent moisture resistance and crack resistance. The iron core is made of amorphous alloy tape, with a rectangular cross-section and three-frame three-column structure.
 

Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type TransformerOur company's transformer design and development technology is based on extensive physical model experiments. We have independently developed software for calculating transformer magnetic leakage, short-circuit mechanical forces, and load losses. This enables comprehensive optimization of the transformer's electrical performance, providing users with the lowest lifecycle operational costs. Structural design utilizes three-dimensional finite element analysis software to analyze transformer cores, coils, and components, ensuring enhanced mechanical strength, short-circuit resistance, and reduced noise.

 

Features:

Low no-load loss (approximately 70% reduction compared to current SCB10 dry-type transformers). High efficiency, low noise, significant energy savings. Small volume, light weight. Safe, reliable, pollution-free, capable of direct operation at load centers. High mechanical strength, strong short-circuit resistance, low partial discharge, good thermal stability. High reliability, long service life. Good heat dissipation performance, strong operational capability, capacity can be increased when forced air-cooled. Good moisture resistance, suitable for operation in high humidity and other harsh environments. Environmentally friendly, flame-retardant, explosion-proof, maintenance-free. Transformers with capacities of 200kVA and above have foil-wound low-voltage coils, high-voltage coils wound with 180°C high-strength enameled wire, and are cast with epoxy resin for excellent moisture resistance and crack resistance. The core is made of amorphous alloy strip wound into a rectangular cross-section, three-phase three-column structure.
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
 

 

production process

 

1.Amorphous alloy material has no crystalline structure and is a type of metal processed using special rapid quenching technology. It exhibits low magnetization power, good heat resistance, and soft magnetic properties. Transformers made with this material are a new type of energy-saving transformer, reducing no-load losses by over 70% compared to current S11 distribution transformers.
Wound core processSc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type TransformerSc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
2.Coil
    amorphous oil-immersed coil

The coils are rectangular, with high-voltage coils wound with alkyd enameled wire. Low-voltage coils are wound with wires or foils to enhance the transformer's ability to withstand short circuits.Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type TransformerSc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer

 

 

Detailed Photos
 
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
 
Product Parameters
product model High voltage
(kV)
high voltage tapping range.(%) low voltage(kV) Connection group designation no-load loss
(W)
load loss no-load current
(%)
short-circuit impedance
(%)
100ºC(B) W125ºC(F) 145ºC(H)
SCBH15-30         70 670 710 760 1.6  
SCBH15-50         90 940 1000 1070 1.4  
SCBH15-80         120 1290 1380 1480 1.3  
SCBH15-100         130 1480 1570 1690 1.2  
SCBH15-125         150 1740 1850 1980 1.1  
SCBH15-160 6       170 2000 2130 2280 1.1  
SCBH15-200       200 2370 2530 2710 1.0 4
SCBH15-250 6.3       230 2590 2760 2960 1.0  
SCBH15-315       280 3270 3470 3730 0.9  
SCBH15-400 6.6 ±5or     310 3750 3990 4280 0.8  
SCBH15-500     0.4 Dyn11 360 4590 4880 5230 0.8  
SCBH15-630 10 ±2×2.5     420 5530 5880 6290 0.7  
SCBH15-630         410 5610 5960 6400 0.7  
SCBH15-800 10.5       480 6550 6960 7460 0.7  
SCBH15-1000 11       550 7650 8130 8760 0.6  
SCBH15-1250       650 9100 9690 10370 0.6 6
SCBH15-1600         760 11050 11730 2580 0.6  
SCBH15-2000         1000 13600 14450 15560 0.5  
SCBH15-2500         1200 16150 17170 18450 0.5  
SCBH15-1600         760 12280 12960 13900 0.6  
SCBH15-2000         1000 15020 15960 17110 0.5 8
SCBH15-2500         1200 17760 18890 20290 0.5  
Note: When using other connection group designations, specific requirements are to be determined through consultation between the manufacturer and the user.
After Sales Service

1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.

2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.

3.We use quality authentic materials, process and manufacture in strict compliance with ISO9001:2000 international quality management to ensure the quality of excellence and the smooth installation!

Packaging & Shipping
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer

 

 
Certifications

 

Sc (B) 20kv Distribution Transformer Epoxy Resian Cast 3150kVA Dry Type Transformer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now