Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 1/Piece
Request Sample
Manufacturer/Factory, Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv
  • Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv
  • Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv
  • Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Product Parameters
  • Structure Diagram
  • Service Environment
  • Certifications
Overview

Basic Info.

Application
Substation, Power Plant, AC&DC
Size
Large
Operation Voltage
High Voltage
Shape
Spiral
Material
Ceramic
Certification
ISO9001, CCC
Rated Voltage
33kv-144kv
Customization
Acceptable
Language
Chinese, English, Russian
Price
Negotiable
Transport Package
Cartons or Others
Specification
As required
Trademark
HEZC
Origin
China
Production Capacity
50000pieces/Year

Product Description

Company Profile

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv

Product Description
Porcelain-clad metal oxide surge arrester is a reliable pressure release device with good structure, long-lasting sealing, more uniform potential distribution.


Type description:
Y10WZ*-1O2/2661
Y: Porcelain-clad metal oxide surge
10: Nominal discharge current
W: W:No Gap; C: Series Gap; B: Parallel Gap
Z: S: Power ; Z: Substation; X: Circuit; R:Capacitor bank
    T: Electrified railway F:GIS    L: Direct current
*: Sequence no.
102: Rated voltage (kV)
266: Nominal maximum residual voltage under lightning impulse current(kV)
W: G:Plateau type; W:Fouling resistant; K: Seismic T:Damp-heat type
Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv
Product Parameters
Typical Product Parameters of Transformer Neutral Point Metal Oxide Surge Arresters with Porcelain Clad for 33kV-144kV
(Implementing Standard:GB/T 11032)
Type Rated voltage (kVr.m.s.) Operational voltage
(kVr.m.s.)
Operating impulse current residual voltage Residual voltage of lightning impulse current Dc 1mA reference voltage 2ms square wavecurrent capacity W.t. (KG) Creepage distance
(mm)
Y1.5W-33/85 33 26 80    85 50  400  54.0   1256
Y1.5W-42/102 42 34 95   102 60  400  54.0   1256
Y1.5W-60/144 60 48 135   144 85 400  75.4 1800
Y1.5W-72/186 72 58 174 186 103 400 75.4 1800
Y1.5W-96/260 96 77 243 260 137 400 138.0 3150
Y1.5W-144/320 144 116 299 320 205 400 134.5 3200

 
 
Structure Diagram
Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv
Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv
Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv

                      
              Figure 1                                                          Figure 2                                                                 Figure 3

                               Figure 4                                                                                                             Figure 6

Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv
Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv
 
Service Environment

1. The ambient temperature is not higher than +40ºC, not lower than -40ºC;
2. Radiation from sunlight:

Note: The effect of maximum solar exposure (1.1kw/m2) has been taken into account by preheating the test in the type test. If there are other heat sources in the vicinity of the arrester, the use of the arrester must be negotiated by the supply and demand parties.
3. The altitude does not exceed 3000m;
4. The frequency of the power supply is not less than 48Hz, not more than 62Hz;
5. The power frequency voltage applied between the terminals of the arrester for a long time should not exceed the continuous operating voltage of the arrester;
6. Earthquake intensity degree 7 and below;
7. The maximum wind speed does not exceed 35m/s.

 
Certifications

 

Transformer Neutral Point Porcelain Metal Oxide Arrester with Porcelain Clad for 33kv-144kv

 

 

 











 

 
 
 
 
 