Customization: | Available |
---|---|
Application: | Power, Electronic, Instrument, Lighting, Rectifier, Audio |
Phase: | Three |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
66KV/110kV Power Transformer The 66KV/110kV transformer is a high-voltage oil-immersed transformer with a core-type structure. It can be classified by phase number into single-phase transformers and three-phase transformers; by voltage regulation method into on-load tap-changing transformers and no-load tap-changing transformers; by winding coupling method into power transformers and autotransformers; by the number of windings into double-winding, three-winding, and three-winding plus balance winding transformers. Additionally, it includes special types such as split transformers and combined transformers. The product is designed according to IEC international standards, IEEE standards, and current national standards.
Main Features
Their main features include:
1. Low noise, reducing noise pollution to the environment;
2. Low partial discharge, ensuring stable and reliable operation of the transformer;
3. Low temperature rise, with strong overloading capacity;
4. Low loss, optimizing the energy structure;
5. No leakage, with high sealing performance of the transformer;
6. Maintenance-free, reducing the customer's maintenance costs;
7. High impedance, with high short-circuit resistance, enhancing the safety performance of the transformer;
8. Utilization of intelligent components, incorporating intelligent power station design technology.
Rated capacity (kVA) |
Voltage ratio (kV) HV MV LV |
Connection Symbol |
No-load loss (kW) |
No-load current (%) |
Full-load loss (kW) |
Impedance (%) |
|||
step-down |
step-up |
||||||||
6300 | 110 ±8×1.25% |
35 37 38.5 ±2×2.5% or ±5% |
6.3 6.6 10.5 |
YNyn0d11 | 12 | 0.6 | 47 | 10.5 17~18 6.5 |
17~18 10.5 6.5 |
8000 | 14.4 | 0.6 | 56 | ||||||
10000 | 17.1 | 0.55 | 66 | ||||||
12500 | 20.2 | 0.55 | 78 | ||||||
16000 | 24.2 | 0.5 | 95 | ||||||
20000 | 28.6 | 0.5 | 112 | ||||||
25000 | 33.8 | 0.45 | 133 | ||||||
31500 | 40.2 | 0.45 | 157 | ||||||
40000 | 48.2 | 0.4 | 189 | ||||||
50000 | 56.9 | 0.4 | 225 | ||||||
63000 | 67.7 | 0.35 | 270 |
Rated capacity (kVA) |
HV |
Voltage ratio (kV) HV Tapping Range |
LV |
Connection Symbol |
No-load loss (kW) |
No-load current (%) |
Full-load loss (kW) |
Impedance (%) |
6300 | 110 121 |
±2×2.5% | 6.3 6.6 10.5 11 |
YNd11 | 9.2 | 0.6 | 36.0 | 9 |
8000 | 11.2 | 0.6 | 42.7 | |||||
10000 | 13.2 | 0.55 | 50.4 | |||||
12500 | 15.6 | 0.55 | 59.8 | |||||
16000 | 18.8 | 0.5 | 73.5 | |||||
20000 | 22.0 | 0.5 | 89.1 | |||||
25000 | 26.0 | 0.45 | 105.3 | |||||
31500 | 30.8 | 0.45 | 126.9 | |||||
40000 | 36.8 | 0.4 | 148.9 | |||||
50000 | 44.0 | 0.4 | 184.5 | |||||
63000 | 52.0 | 0.35 | 222.3 |
Rated capacity (kVA) |
HV |
Voltage ratio (kV) HVTapping Range |
LV |
Connection Symbol |
No-load loss (kW) |
No-load current (%) |
Full-load loss (kW) |
Impedance (%) |
6300 | 63 66 69 |
±8×1.25% | 6.3 6.6 10.5 11 |
YNd11 | 10 | 0.6 | 36.0 | 9 |
8000 | 12 | 0.6 | 42.7 | |||||
10000 | 14.2 | 0.55 | 50.4 | |||||
12500 | 16.8 | 0.55 | 69.8 | |||||
16000 | 20.2 | 0.5 | 73.5 | |||||
20000 | 24 | 0.5 | 89.1 | |||||
25000 | 28.4 | 0.45 | 105.3 | |||||
31500 | 33.7 | 0.45 | 126.9 | |||||
40000 | 40.3 | 0.4 | 148.9 | |||||
50000 | 47.6 | 0.4 | 184.9 | |||||
63000 | 56.2 | 0.35 | 222.3 |
Service environment:
1.Device types: outdoor type
2.Type of Voltage Regulation: Off-circuit or On-Ioad
3.Tapping Range: ±5 % ±2x2.5 % ±4x2.5 %
4.Frequency: 50Hz or 60Hz
5.Phases: Three or single
6.Connection Symbol: Dyn11,Yyn0 ( or as requested)
7.Short- circuit Impedance: Standard Impedance
8.Altiude is not exceeding 1000m,ambient temperature not exceeding 40OC. If it can't meet such conditions,we will modulate parameters in accordance with standard.
It is used to raise the power generated by the power plant to 110 kV /66KV high voltage for efficient transmission over long distances. In substations, they regulate the voltage to ensure a stable supply of electricity to industrial, commercial and residential customers. At the same time, in power plants, these transformers raise the power to a voltage level suitable for long-distance transmission, ensuring the stable operation of the grid.
1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.
2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.
3.We use quality authentic materials, process and manufacture in strict compliance with ISO9001:2000 international quality management to ensure the quality of excellence and the smooth installation!
Production Equipment
Certificate