Customization: | Available |
---|---|
Breaking Capacity: | High Voltage Circuit Breakers |
Operation: | Electric Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
1. Outdoor;
2. Ambient air temperature :-25ºC~+40ºC (special requirement: -40ºC~+40ºC);
3. Altitude: does not exceed 2500m;
4. Relative humidity: the daily average is not more than 95%, the monthly average is not more than 90%;
5. The magnitude of the earthquake was no more than 8 degrees;
6. No fire, explosion, serious pollution, chemical corrosion and violent vibration.
7. Natural wind speed no more than 34m/s.
No. | Item | Unit | Data | ||||||||||||||||
1 | Rated voltage | KV |
72.5 | ||||||||||||||||
2 | Rated power frequency withstand voltage (1min) | 160 | |||||||||||||||||
176 | |||||||||||||||||||
3 | Rated lightning impulse withstand voltage | 350 | |||||||||||||||||
385 | |||||||||||||||||||
4 | Power frequency under zero gauge pressure of SF6(5min) | 55 | |||||||||||||||||
5 | Rated frequency | Hz | 50 | ||||||||||||||||
6 | Rated current | A | 3150 | ||||||||||||||||
7 | First pole factor | 1.5 | |||||||||||||||||
8 | Rated peak withstand current | KA | 100 | ||||||||||||||||
9 | Rated short-circuit breaking current | 40 | |||||||||||||||||
10 | Rated pull-out breaking current | 10 | |||||||||||||||||
11 | Rated short-time withstand current | 40 | |||||||||||||||||
12 | Rated short-circuit CO current | 100 | |||||||||||||||||
13 | Rated operational sequence | O-0.3s-CO-180s-CO | |||||||||||||||||
14 | First pole factor | 1.5 | |||||||||||||||||
15 | Opening time | ms | 30±3 | ||||||||||||||||
16 | Closing time | 75±8 | |||||||||||||||||
17 | Main circuit resistance | UΩ | ≤40 | ||||||||||||||||
18 | Rated SF6 gas pressure (20ºC gauge pressure) | MPa | 0.6/0.5 | ||||||||||||||||
19 | Alarm/lowest function pressure (20ºC gauge pressure) | 0.55 | |||||||||||||||||
20 | Locking pressure (20ºC gauge pressure) | 0.55 | |||||||||||||||||
21 | SF6 gas annual leakage percent | ≤0.5% | |||||||||||||||||
22 | SF6 gas moisture content(V/V) | u L/L | ≤150 | ||||||||||||||||
23 | Mechanical life | Time | 6000 | ||||||||||||||||
24 | SF6 gas weight | Kg |
10 | ||||||||||||||||
25 | Breaker weight | 1400 |
1. It can be used for three-phase neutral ground or neutral point ungrounded AC system;
2. The circuit breaker adopts a three-pole porcelain pillar structure, the three poles are equipped with a spring operating mechanism, centered arrangement, and the three poles are connected;
3. The self-energy arc extinguishing principle is adopted, and the optimized design is carried out in the circuit breaker motion system, which effectively improves the mechanical efficiency and minimizes the operation work;
4. SF6 density controller (with pressure gauge) monitors the density of SF6 gas in the circuit breaker and sends a control signal, with temperature compensation function. When the ambient temperature changes and the SF6 gas pressure changes, the controller indicates the same value. Only when SF6 gas leakage causes a change in gas density, the controller will issue an alarm and lock signal;
5. The spring operating mechanism is equipped with strong breaking ability, small operation power and high reliability. The control cabinet is connected to the base through 6 M20 bolts, and there are moisture-proof and waterproof devices at the connection between the output shaft of the mechanism and the B-phase arm and at the exit of the secondary line;
6. On the inner panel of the control cabinet, there are manual opening and closing buttons, remote to local transfer switches, energy storage motor switch circuit breaker status signs;
7. Suitable for high altitude environment (2500m).
After-sales Service
1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.
2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.