Outdoor High Voltage Sf6 Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • Outdoor High Voltage Sf6 Circuit Breaker
  • Outdoor High Voltage Sf6 Circuit Breaker
  • Outdoor High Voltage Sf6 Circuit Breaker
  • Outdoor High Voltage Sf6 Circuit Breaker
  • Outdoor High Voltage Sf6 Circuit Breaker
  • Outdoor High Voltage Sf6 Circuit Breaker
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
  • Product Parameters
  • Installation Instructions
  • After Sales Service
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
LW8-40.5
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Rated Voltage
40.5kv
Rated Current
2000A
Transport Package
Wooden Box
Specification
As manufacturer′ s design
Trademark
HZEC
Origin
China
Production Capacity
2000 Piece/Pieces Per Month

Product Description

Product Description

Technical Specifications of the LW8-40.5 Type High Voltage SF6 Circuit Breaker (Tank Type)

The LW8-40.5 type outdoor high voltage SF6 circuit breaker (hereinafter referred to as "circuit breaker") is a three-phase AC 50Hz outdoor high voltage electrical device. It is equipped with a CT14 type spring operating mechanism and is suitable for the control and protection of 35kV power transmission and distribution systems. This product features high breaking capacity, safety and reliability, frequent operation capability, and low maintenance requirements. It can also be used for tie breakers and capacitor bank switching applications.
 

Outdoor High Voltage Sf6 Circuit Breaker
Outdoor High Voltage Sf6 Circuit Breaker
 
Detailed Photos
Outdoor High Voltage Sf6 Circuit Breaker
Outdoor High Voltage Sf6 Circuit Breaker
Outdoor High Voltage Sf6 Circuit Breaker
Outdoor High Voltage Sf6 Circuit Breaker
Outdoor High Voltage Sf6 Circuit Breaker
Outdoor High Voltage Sf6 Circuit Breaker

 

Company Profile

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable transformer manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations and high and low voltage complete sets of equipment.The equipment put into production and operation of the project advocates energy saving, intelligence, information and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center,with 71 utility model patents and 15 invention patents.With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa and other regions, covering more than 40 countries.
Outdoor High Voltage Sf6 Circuit Breaker

Operating Environmental Conditions

1 Sunlight: 1000 W/m²
2 Relative Humidity: Daily average: not exceeding 95%; Monthly average: not exceeding 90%
3 Wind Speed: Not exceeding 34 m/s
4 Earthquake Resistance: Horizontal acceleration: 0.250 g; Vertical acceleration: 0.125 g
5 Pollution Level: Class I (25 mm/kV)
6 Ice Thickness: 10 mm (when wind speed does not exceed 15 m/s)
7 Protection Level: IP5X
 

Product Parameters
 Item Parameter
 Altitude 1000m 2000m
Ambient Temperature -30ºC-40ºC -40ºC-40ºC -30ºC-40ºC -40ºC-40ºC
Rated Voltage 40.5kV
Rated Current 2000A
Rated Short-Circuit Breaking Current (Isc) 31.5kA 25kA 31.5kA 25kA
Rated Short-Circuit Making Current (Peak Value) 80kA 63kA 80kA 63kA
Rated Short-Time Withstand Current (RMS Value) 3s 31.5kA 25kA 31.5kA 25kA
Rated No-Voltage Breaking Current IscX25%(kA)
 1-Minute Power-Frequency Withstand Voltage (RMS Value)  Across Contacts 95+24  kV 95kV 95kV 95kV
To Ground 95kV 95kV 95kV 95kV
Lightning Impulse Withstand Voltage (Peak Value)  Across Contacts 185+33 kV 185kV 185kV 185kV
To Ground 185kV 185kV 185kV 185kV
Mechanical Life 3000Times
 Full Opening Time ≤80ms
 Electrical Life 20Times
  • Structure & Working 

    The circuit breaker adopts a parallel transmission method and is equipped with a CT14 spring operating mechanism. It has a three-phase separated, floor-standing tank structure with a compressed air arc extinguishing chamber. The three-phase gas is connected through copper pipes. The circuit breaker consists of outlet bushings, current transformers, arc extinguishing chamber, housing, adsorber, transmission box, linkage, chassis, and spring operating mechanism.

  • Arc Extinguishing Principle: The arc extinguishing principle uses SF6 gas, which has excellent arc extinguishing and insulating properties, as the arc extinguishing and insulating medium. The arc extinguishing chamber is of single compressed air structure with an axial double-blow arc principle: the circuit breaker cylinder moves relative to the stationary piston, and the SF6 gas in the cylinder is charged with SF6 gas at a pressure of 0.45 MPa gauge. During the opening process, the movable piston compresses, creating a pressure difference with the gas outside the pressure cylinder. The high-pressure SF6 gas flow generates a strong arc-blowing effect through the nozzle, forcing the arc to extinguish at the zero-crossing point.

  • Current Transformer: The circuit breaker can be equipped with 12 bushing-type current transformers for measurement purposes, connected to the outer casing. Each phase has two transformers installed on either side of the break, with cast aluminum housing filled with SF6 gas. The conductive rod forms the primary circuit, and the secondary circuit wires are routed through well-sealed terminal boards to the exterior. The terminal boards and the connecting wires to the mechanism box are protected by enclosures and steel pipes to prevent direct contact with the atmosphere. The current transformer ratio can be customized according to user requirements: 100~.

Installation Instructions

 

Outdoor High Voltage Sf6 Circuit BreakerOutdoor High Voltage Sf6 Circuit Breaker
After Sales Service

1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.

2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.

3.We use quality authentic materials, process and manufacture in strict compliance with ISO9001:2000 international quality management to ensure the quality of excellence and the smooth installation!
 

Packaging & Shipping

 

Outdoor High Voltage Sf6 Circuit Breaker
Outdoor High Voltage Sf6 Circuit Breaker
Outdoor High Voltage Sf6 Circuit Breaker
 
Outdoor High Voltage Sf6 Circuit Breaker
Outdoor High Voltage Sf6 Circuit Breaker
Outdoor High Voltage Sf6 Circuit Breaker
FAQ

 

Outdoor High Voltage Sf6 Circuit Breaker
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier