Indoor Outdoor 110kv 220kv Transformer Neutral Point Grounding Protection Device

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Manufacturer/Factory, Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • Indoor Outdoor 110kv 220kv Transformer Neutral Point Grounding Protection Device
  • Indoor Outdoor 110kv 220kv Transformer Neutral Point Grounding Protection Device
  • Indoor Outdoor 110kv 220kv Transformer Neutral Point Grounding Protection Device
  • Indoor Outdoor 110kv 220kv Transformer Neutral Point Grounding Protection Device
  • Indoor Outdoor 110kv 220kv Transformer Neutral Point Grounding Protection Device
  • Indoor Outdoor 110kv 220kv Transformer Neutral Point Grounding Protection Device
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Product Parameters
  • Properties
  • Service Environment
  • Installation Instructions
  • Certifications
Overview

Basic Info.

Model NO.
ZJB
Arc-extinguishing Medium
Oil-immersed Type
Installation
Fixed
Structure
ACB
Poles Number
3
Type
Grounding Protection Device
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CCC
Customization
Acceptable
Currency
RMB or USD
Language
Chinese, English, Russian
Loading Port
It Depends
Rated Voltage
35kv 110kv 220kv
Transport Package
Wooden Case or Others
Specification
As required
Trademark
HZEC
Origin
China
Production Capacity
500000 Sets/Year

Product Description

Company Profile

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
Indoor Outdoor 110kv 220kv Transformer Neutral Point Grounding Protection Device
Product Description
Indoor Outdoor 110kv 220kv Transformer Neutral Point Grounding Protection Device
The transformer neutral point gap grounding protection device is used for 35KV, 110KV, 220KV, 330KV, 500KV power transformer neutral point to achieve the transformer neutral point grounded or ungrounded operation of two different modes of operation; Therefore, the damage to the transformer caused by the rise of the neutral voltage caused by the system failure can be avoided. This product is widely used in electric power, metallurgy, petrochemical, construction, environmental protection and other fields.

Current transformer selection: dry current transformer cast with epoxy resin. The current transformer is installed in the stainless steel box, which is not affected by the environmental climate and has a long service life, so that the protection will not appear misoperation or rejection and is stable and reliable.
 
Product Parameters
  
Model Rated voltage of transformer(kV) Neutral point withstand voltage Disconnector Oxide zinc arrester Discharging gap Current transformer
Lightning full wave and chopped impulse withstand voltage (kv) 1min power frequency(kV) Rated current (A) Operational mechanism Rated voltage (kV) Continuous working voltage (kV) DC 1mA reference voltage ≥ 8/20µs lightning impulse residual current (kV) Power frequency discharging voltage(kV) Type test Transformation ratio
JXB-110 110 250 95 400 CS8-5 (manual) or CJ6 (Electrical)
 
72 58 103 186 83 Epoxy resin poured completely enclosed pillar type 10kV (110/5, 200/5, 300/5, 400/5, 500/5, 600/5)
JXB-220 220 320 200 600 144 116 205 320 166
JXB-330 330 440 292 600 CJ6 (Electrical) 207 166 292 440 252
Properties
1. Meet the standards, professional manufacturing;
2. Novel design, overall installation;
3. Effective protection, stable characteristics;
4. Flexible assembly, easy to use;
5. strong technical force, good service.
Service Environment

1. Suitable for indoor and outdoor;
2. Ambient temperature: not lower than -40ºC, not higher than +55ºC; Relative humidity: not more than 95% (25ºC);
3. The altitude does not exceed 4000m, beyond 4000m can be customized according to the actual situation;
4. Areas with seismic intensity of 8 degrees and below; Wind speed does not exceed 35m/s;
5. Power grid frequency: 58 ~ 62Hz (60Hz system), 48 ~ 52Hz (50Hz system);
6. The air in the installation site should not contain chemical gases and vapors, and there is no dust.

Installation Instructions
Indoor Outdoor 110kv 220kv Transformer Neutral Point Grounding Protection Device
Model H W L Base hole diameter Base hole distance
JXB-110 1315 370 1300 4×Ø20 450×450
JXB-220 1900 370 1300 4×Ø20 450×450
JXB-330 Customizable

 

Certifications

Indoor Outdoor 110kv 220kv Transformer Neutral Point Grounding Protection Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier