Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Manufacturer/Factory, Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
  • Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
  • Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
  • Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
  • Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
  • Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Product Parameters
  • Product Features
  • Customer Case
  • Packaging & Shipping
  • Certifications
Overview

Basic Info.

Model NO.
LW9-66KV
Arc-extinguishing Medium
SF6
Installation
Fixed
Structure
ACB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CCC
Rated Voltage
66kv
Rated Current
2000A
Rated Frequency
50Hz
Customization
Acceptable
Language
Chinese, English, Russian
Protection Class
IP5xw
Loading Port
It Depends
Customized Processing.
Yes
Transport Package
Wooden Case or Others
Specification
Designed According to Supplier Specifications
Trademark
HZEC
Origin
China
Production Capacity
300000sets/Year

Product Description

Company Profile

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker

 

Product Description
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker

The 66kV SF6 circuit breaker, model LW9-66, is a porcelain column type high-voltage AC sulfur hexafluoride circuit breaker equipped with the CT20 spring operating mechanism. It is manufactured by  High Voltage Switch Co., Ltd. The breaker adopts a self-energy arc-extinguishing principle and has a single-break structure. The three poles of each circuit breaker are mounted on a single frame, achieving three-phase mechanical linkage through the transmission mechanism.1. Daily temperature difference: ≤25 ºC;
2. Sunshine: 0.1W /cm2;
3. Relative humidity: daily average ≤95%; Monthly average ≤90%
4. Wind speed: 34 m/s;
5. Earthquake resistance: horizontal acceleration 0.250g; Vertical acceleration 0.125g;
6. Pollution level: III (25mm/kV), IV (31mm/kV);
7. Ice thickness: 10 mm (wind speed is not more than 15m/s);
8. Protection level: IP5XW.

 

Product Overview:

The LW9-66kV SF6 circuit breaker is a porcelain column type high-voltage AC sulfur hexafluoride circuit breaker with the CT15 spring mechanism. The three poles of the circuit breaker are assembled on a single frame, with each pole consisting of a single break structure. All movable components of the three-pole arc extinguishing chambers are mechanically connected to the spring operating mechanism.

The electrical control, protection, signaling devices, SF6 gas pressure monitoring system, and the spring mechanism are all housed inside the control box (2-5). The arc extinguishing chamber (2-2) is connected to the inner cavity of the support porcelain bushing (2-3), filled with SF6 gas at a rated pressure of 0.50 MPa at 20°C. The gas is connected to the gas density controller (2-10) inside the control box through gas pipelines. When the SF6 gas pressure drops to 0.45 MPa at 20°C, an alarm signal is triggered, indicating the need for gas replenishment. When the SF6 gas pressure drops to 0.40 MPa at 20°C, the high-voltage circuit breaker will trip.

Technical Specifications:

  • Rated short-circuit breaking current: 31.5kA
  • Rated short-time withstand current: 31.5kA
  • Rated insulation level: 1-minute power frequency withstand voltage (effective value) (20°C, 0.4MPa SF6 gas) 160kV + 42kV between breaks, 160kV to ground (same for dry and wet tests)
  • Lightning impulse withstand voltage (peak value): 1.2/50μs (20°C, 0.4MPa SF6 gas) 350kV + 60kV between breaks, 350kV to ground
  • SF6 gas rated pressure (20°C): 0.50MPa
  • Alarm pressure: 0.45MPa
  • Lockout pressure: 0.40MPa
  • Moisture content: ≤150ppm (v/v)
  • Annual leakage rate: ≤1%

The outdoor LW9-72.5 breaker produced by High Voltage Switch Co. is a porcelain column type high-voltage AC SF6 circuit breaker equipped with the CT20 spring operating mechanism. It utilizes a self-energy arc extinguishing principle and features a single-break structure. The three poles of each breaker are mounted on a single frame, achieving three-phase mechanical linkage through the transmission mechanism. The electrical control system allows for both remote and local operations.

Product Parameters
No. Name   Unit   Parameters
Altitude     m 1000    2000 
Temperature     -30ºC~40ºC -40ºC~40ºC -30ºC~40ºC -40ºC~40ºC
Rated voltage     kV 126 
Rated frequency     Hz 50 
Rated current     A 3150 
Rated short-circuit breaking current, Isc     kA 40  31.5     40    31.5 
Rated short-circuit closing current (peak)     kA 100  80  100    80 
8
9
10
11
12
13
Rated short-time withstand current (valid value)     kA 40  31.5     40    31.5 
Rated short-circuit lasting time   S    4 
Rated peak withstand current     kA 100  80  100    80 
Close-in fault breaking current     kA  bsc 90%,sc75%
Rated out-of-phase breaking current     kA   sc 25%
14  First Breakover Coefficient     15 
15  Rated line-charging switching current     A 31.5 
Earth fault current     A   sc 87%
16  1min Power frequency withstand voltage (valid value) Fracture   kV 230+73 230     230    230 
Pole-to-pole/grounding   230  230     230    230 
17  Lightning impulse withstand voltage (peak) Fracture   kV 550+103 550     550    550 
Pole-to-pole/grounding   550  550     550    550 
18  Rated operational sequence      0-0.3s-C0-180s-CO
19  Opening,closing operation voltage     V DC220;110
20  Tripping coil current     A   2.0;5.8
21  Closing coil current     A   2.0;3.3
22  Motor current     V DC220(AC220)
23  Total breaking time     ms 60.0 
24  Tripping time     ms   35.0    5 
25
26
27
Closing time
Close-open time
    ms
  ms
   ≤100.0
   80.0
28
29
Open-close time      ms
   ms
   300.0 
Opening synchronization     ms ≤4.0
30  Closing synchronization     ms ≤3.0
31  Travel     ms   120.0    ±2.0
              -5.0
Contacting travel   35.0      2.0
32 
SF6 Gas pressure
(20ºC)
Rated pressure
Alarm pressure
MPa 0.60
0.55
0.60
0.35
0.60
0.55
  0.60
  035
Blocking pressure 0.50  0.30  0.50    030 
33  SF6 Gas annual leakage ratio     % ≤0.5
34  Gas moisture content Acceptance value  ppm(v/v)    ≤150
Operation value    ≤300
35  Main loop resistance   μ Q    ≤30.0
36  Radio interference level     μV <500
37  Mechanical life     Time 6000 
38  Electrical life     Time 16 
39
40
Gas weight in each SF6   kg 10 
Weight of each circuit breaker     kg 2100 
Product Features

1. Simple structure, reliable double cylinder self-energy arc extinguishing chamber excellent breaking performance;
2. Reliable insulation performance;
3. Application of spring operating mechanism;
4. Low noise, low maintenance workload;
5. Out-of-phase grounding fault test;
6. Long mechanical life;
7. Good technology transportation;
8. Easy to install.

Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
 

Customer Case

 

Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker


 
Packaging & Shipping
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker
Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker

After-sales Service
1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.

2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.

3.We use quality authentic materials, process and manufacture in strict compliance with ISO9001:2000 international quality management to ensure the quality of excellence and the smooth installation!

Certifications

 

 

Lw9-72.5kv 69kv 66kv High Voltage Outdoor Live Tank Sf6 Circuit Breaker

FQA 
Q1: Are you a factory or a trading company?
A: We are a factory, we have a number of production lines and first-class equipment and machines to ensure that our mass
production.
Q2:What's the advantages of your products?
A: Our product variety, hundreds of specifications, the company has the right to import and export, first-class quality, excellent
service and praise, by domestic and foreign customers.

Q3:Where are your products used? A: They are widely used in petrochemical, aerospace, coal power, railway, metallurgy, shipbuilding, medicine, marine,and other industries.

Q4:Can you accept customization?
A:Yes. Please notify us and confirm the design according to our samples first.

Q5:Can you give me a sample order?
A:Yes, we welcome sample orders to test and check the quality. Mixing samples is acceptable.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier