Customization: | Available |
---|---|
Breaking Capacity: | High Voltage Circuit Breakers |
Operation: | Manual Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
No. |
Item | Uint |
LW9-40.5/T | LW9-72.5/T LW9A-72.5/T |
LW25-126/145/T LW25D-126/145/T LW25o-126/145/T |
LW25-170I/P LW25-170III/P |
LW25-252/T LW25A-252/Y |
LW15C-252/Y | ||
1 | Rated voltage | kV | 40.5 | 72.5 | 126/145 | 170 | 252 | 252 | ||
2 | Rated frequently | Hz | 50 | 50 | 50 | 50 | 50 | 50 | ||
3 | Rated current | A | 3150/4000 | 3150/4000 | 3150 | 3150 | 4000 | 40,005,000 | ||
4 | Rated short-circuit breaking current | kA | 50 | 31.5/40 | 31.5/40 | 40 | 4,050 | 63 | ||
5 | Rated short-circuitmakingcurrent | kA | 125 | 80/100 | 80/100 | 100 | 100,125 | 160 | ||
6 | Rated short-time withstand curentand duration | kA | 50(3s) | 31.5(4s)/40(4s) | 31.5(4s)/40(4s) | 40(3s) | 40(4s),50(4s) | 63(3s) | ||
7 | Rated peak withstand current | kA | 125 | 80/100 | 80/100 | 100 | 80/100 | 160 | ||
8 | Creepage distance | cm/kV | 3.1 | 3.1 | 2.5/3.1 | 2.5,3.1 | 2.5,3.1 | 2.5,3.1 | ||
9 | min.power frequency withstand voltage | Dry test |
Across open breaks | kA | 95+23.4 | 160+42 | 230+95 | 325 | 460+145 | 520+165/520 |
To earth | 95 | 160 | 275 | 325 | 460 | 460 | ||||
Wet test |
Across open breaks | 95 | 160+42 | 230+95 | 325 | 460+145 | 460+145 | |||
To earth | 95 | 160 | 275 | 325 | 460 | 460 | ||||
10 | Rated lighting impulse withstandvoltage |
Across open breaks | 185+33 | 350+59 | 650+100 | 750 | 1050+200 | 1188+226/1188 | ||
To earth | 185 | 350 | 650 | 750 | 1050 | 1188 | ||||
11 | Closing time | ms | 100 | 100 | 100 | 80-110 | 100 | 55-80 | ||
12 | Opening time | ms | ≤30 | ≤30 | ≤30 | 21-30 | ≤30 | ≤25 | ||
13 | Breaking time | ms | ≤60 | ≤60 | ≤60 | ≤60 | ≤60 | ≤60 | ||
14 | CO time | ms | ≤60 | ≤60 | ≤60 | ≤60 | ≤70 | ≤60 | ||
15 | (20ºC)Rated SF6 gas pressure(at 20ºC) | MPa | 0.50 | 0.50;0.40 | 0.50 | 0.60 | 0.60;0.40 | 0.60 | ||
16 | Rated SF6 gas of alarming/lockoutpressure (at 20ºC) | MPa | 0.45/0.40 | 0.45/0.40;0.35/0.30 | 0.45/0.40 | 0.55/0.50 | 0.55/0.50;0.35/0.33 | 0.55/0.50 | ||
17 | Operating mechanism | Spring mechanism |
Spring mechanism |
Spring mechanism |
Spring mechanism |
Spring mechanism/ Hydraulic mechanism |
Hydraulic mechanism |
|||
18 | Applied standards | GB/T 1984,IEC 62271-100 | ||||||||
Note:"T"following the type of product means that the product is equipped with a Spring mechanism; "Y"with a hydraulic operating mechanism. |
||||||||||
LW25D-126/145/T is a kind of 126/145kV single-phase operated circuit breaker. LW25o-126/T is a special circuit breaker for reactivecompensation circuit. LW25A-252/Y is a kind of 252kV three-phase mechanically gang-operated circuit breaker |
Technical Data of 363~550kV Circuit Breakers
No. |
Item | Uint LW25-363/Y | LW25-420/Y | LW15A-363/Y | LW15A-550/Y | ||
1 | Rated voltage | kV | 363 | 420 | 363 | 550 | |
2 | Rated frequently | Hz | 50 | 50 | 50 | 50 | |
3 | Rated current | A | 4000 | 4000 | 5000 | 31,504,000 | |
4 | Rated short-circuit breaking current | kA | 50 | 50 | 63 | 5,063 | |
5 | Rated short-circuit making current | kA | 125 | 125 | 160 | 125,160 | |
6 | Rated short-time withstand current and duration | kA | 50(4s) | 50(4s) | 63 | 50(3s),63(3s) | |
7 | Rated peak withstand current | kA | 125 | 125 | 160 | 125,160 | |
8 | Creepage distance | cm/kV | 3.1 | 2.0,2.5,3.1 | 2.0,2.5,3.1 | 2.0,2.5,3.1 | |
9 | 1min.power frequency withstand voltage |
Across open breaks | kV | 580 | 630+245 | 510+210 | 680+318 |
To earth | 510 | 630 | 510 | 740 | |||
10 | Rated lighting impulse withstand voltage |
Across open breaks | kV | 1175+205 | 1425+345 | 1175+205 | 1675+450 |
To earth | 1175 | 1425 | 1175 | 1675 | |||
11 | Closingtime | ms | 65-95 | ||||
12 | Opening time | ms | 18~30 | ≤20 | |||
13 | Breaking time | ms | ≤50 | ≤40 | |||
14 | CO time | ms | 35~60 | ||||
15 | (20ºC)RatedSF6 gas pressure(at 20ºC) | MPa | 0.60 | ||||
16 | Rated SF6 gas of alarming/lockout pressure(at 20ºC | MPa | 0.55/0.50 | ||||
17 | Operating mechanism | Hydraulic mechanism | |||||
18 | Applied standards | GB/T 1984,IEC 62271-100,DL/T402 | |||||
Note:"T"f ollowing the type of product means that the product isequipped with a Spring mechanism, "Y"with a hydraulic operating mechanism. |
|||||||
LW25D-126/145/T is a kind of 126/145kV single-phase operated circuit breaker. LW25a-126/T is a special circuit breaker for reactive compensationcircuit. LW25A-252/Y is a kind of 252kV three-phase mechanically gang-operated circuit breaker |
No. | Item | Unit | Technical Data |
1 | Volage of control circuit | V | DC 220/DC 110 |
2 | Current of trip coil | A | 2~2.5/5.8 |
3 | Current of close coil | A | 2/3.3 |
4 | Voltage of energy-store motor | V | DC220/DC110(AC220) |
5 | Power of energy-store motor | W | 450 |
6 | Voltage of heater | V | AC220 |
7 | Power of heater | W | 100 |
No. | Item | Unit | Technical Data |
1 | Volage of control circuit | V | DC220/DC 110 |
2 | Current of trip coil | A | 1.43/3.06 |
3 | Current of close coil | A | 1.43/3.06 |
4 | Voltage of energy-store motor |
V | DC 220/DC 110/AC 220 |
5 | Power of energy-store motor |
W | 470/1300 |
6 | Voltage of heater | V | AC220 |
7 | Power of heater | W | 100 |
8 | Rated mechanical operating pressure |
MPa | 44.9/53.1 |
CYA3,CYA4 |
1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.
2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.
3.We use quality authentic materials, process and manufacture in strict compliance with ISO9001:2000 international quality management to ensure the quality of excellence and the smooth installation!