Customization: | Available |
---|---|
Application: | Electronic, Instrument, Position Sensor, Audio, Lighting |
Type: | Current Transformer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
1. It is organic insulation type product.The external insulation is silicone rubber petticoat.
2. Electric field evenly distributed, small partial discharge and stable, small dielectric loss.
3. The current ratio can be adjusted easily by changing the wiring method at shielding enclosure through series or parallel connection.
4. The product has nooil, no ceramic, no gas, pollution-free.
5. Barely need for maintenance. Just need to measure capacitance and dielectric loss factor every 2~3 years.
6. The base uses spray painting or hot galvanizing, which gives a high degree of corrosion resistance.
7. Fasteners and nameplate are stainless steel.
Rated voltage,kV | 33 or 35 | 66 or 69 | 110 or 115 | 132 or 138 | 150 | 220 or 230 |
Highest voltage for equipment,kV | 36 or 40.5 | 72.5 | 123 or 126 | 145 | 170 | 245 or 252 |
Rated frequency,Hz | 50 or 60 | |||||
Rated power frequency withstand voltage,kV | 95 | 160 | 230 | 275 | 325 | 460 |
Rated lightning impulse voltage,kV | 200 | 350 | 550 | 650 | 750 | 1050 |
Flashover distance,mm | 385 | 700 | 1100 | 1300 | 500 | 2100 |
Cree.distance,mm | W1:810 W2:1020 W3:1260 |
W1:1450 W2:1820 W3:2250 |
W1:2520 W2:3150 W3:3910 |
W1:2900 W2:3630 W3:4500 |
W1:3400 W2:4250 W3:5270 |
W1:5040 W2:6300 W3:7820 |
Mechanical load,N | 3000 | 3000 | 3000 | 3000 | 3000 | 4000 |
Rated primary current,A | 5~2500 | |||||
Rated secondary current,A | 1;2;5 | |||||
Accuracy class | 0.1;0.2;0.5;0.2S;0.5S;5P;10P;PX... | |||||
Rated output(recommended value),VA | 1A:10~30 VA 2A:10~30 VA 5A:15~50VA |
|||||
Instrument security factor FS | 5:10 | |||||
Accuracy limit factors ALF | 10,15,20,25,30 | |||||
Short-time thermal current(Maximum),kA | 40kA/3s |
1. Ambient temperature:-40ºC- +45ºC
2. Altitude:≤2000m(If above 2000m,the product will be customized according to user's request)
3. Pollution level: II, III, IV.