Transformer Neutral Point Clearance Protection Gap for 110kv 220kv Power Transformer

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • Transformer Neutral Point Clearance Protection Gap for 110kv 220kv Power Transformer
  • Transformer Neutral Point Clearance Protection Gap for 110kv 220kv Power Transformer
  • Transformer Neutral Point Clearance Protection Gap for 110kv 220kv Power Transformer
  • Transformer Neutral Point Clearance Protection Gap for 110kv 220kv Power Transformer
  • Transformer Neutral Point Clearance Protection Gap for 110kv 220kv Power Transformer
  • Transformer Neutral Point Clearance Protection Gap for 110kv 220kv Power Transformer
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Product Parameters
  • Properties
  • Service Environment
  • Installation Instructions
  • Certifications
Overview

Basic Info.

Model NO.
BJB
Arc-extinguishing Medium
Oil-immersed Type
Installation
Fixed
Structure
ACB
Poles Number
3
Type
Grounding Protection Device
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CCC
Customization
Acceptable
Currency
RMB or USD
Language
Chinese, English, Russian
Loading Port
It Depends
Rated Voltage
110kv 220kv
Transport Package
Wooden Case or Others
Specification
As required
Trademark
HZEC
Origin
China
Production Capacity
500000 Sets/Year

Product Description

Company Profile

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
Transformer Neutral Point Clearance Protection Gap for 110kv 220kv Power Transformer
Product Description
 The transformer neutral gap protection device is specially designed for 110KV, 220KV and 330KV power transformer neutral points to achieve two different operation modes of transformer neutral ground operation or ungrounded operation.
Transformer Neutral Point Clearance Protection Gap for 110kv 220kv Power Transformer
Transformer Neutral Point Clearance Protection Gap for 110kv 220kv Power Transformer
 
Product Parameters
  
Model Rated voltage of transformer(kV) Neutral point withstand voltage Disconnector Oxide zinc arrester Discharging gap Current transformer
Lightning full wave and chopped impulse withstand voltage (kv) 1min power frequency(kV) Rated current (A) Operational mechanism Rated voltage (kV) Continuous working voltage (kV) DC 1mA reference voltage ≥ 8/20µs lightning impulse residual current (kV) Power frequency discharging voltage(kV) Type test Transformation ratio
BJB-110 110 250 95 400 CS8-5 (manual) or CJ6 (Electrical)
 
72 58 103 186 83 Epoxy resin poured completely enclosed pillar type 10kV (110/5, 200/5, 300/5, 400/5, 500/5, 600/5)
BJB-220 220 400 200 600 144 116 205 320 166
Properties
1. Meet the standards, professional manufacturing;
2. Novel design, overall installation;
3. Effective protection, stable characteristics;
4. Flexible assembly, easy to use;
5. strong technical force, good service.
Service Environment

1. Suitable for indoor and outdoor;
2. Ambient temperature: not lower than -40ºC, not higher than +55ºC; Relative humidity: not more than 95% (25ºC);
3. The altitude does not exceed 3000m, beyond 3000m can be customized according to the actual situation;
4. Areas with seismic intensity of 7 degrees and below; Wind speed does not exceed 35m/s;
5. Power grid frequency: 58 ~ 62Hz (60Hz system), 48 ~ 52Hz (50Hz system);
6. The air in the installation site should not contain chemical gases and vapors, and there is no dust.

Installation Instructions

1. The device can be lifted using the four mounting holes in the base. Do not bind the lifting rope to the porcelain column to prevent damage to the device.
2. The channel steel bracket for fixing the operating mechanism and the steel pipe from the operating mechanism to the rotating shaft of the conductive rod of the isolation switch are not within the scope of supply of this device. All are made by the installation unit on site, and the length and size are determined on site.
3. The device should be grounded reliably.
4. The shape and size of the product shall be subject to the actual supply.
5. Install the isolation switch according to the installation instructions of GW8 or GW13 series neutral point isolation switch.Transformer Neutral Point Clearance Protection Gap for 110kv 220kv Power Transformer