Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Manufacturer/Factory, Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
  • Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
  • Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
  • Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
  • Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
  • Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Service Environment
  • Product Parameters
  • Customer Case
  • Packaging & Shipping
  • Certifications
Overview

Basic Info.

Model NO.
LW-252
Arc-extinguishing Medium
SF6
Installation
Fixed
Structure
ACB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CCC
Rated Voltage
252kv
Rated Current
4000A
Rated Frequency
50Hz
Customization
Acceptable
Language
Chinese, English, Russian
Loading Port
It Depends
Transport Package
Wooden Case or Others
Specification
Designed According to Supplier Specifications
Trademark
HZEC
Origin
China
Production Capacity
300000sets/Year

Product Description

Company Profile

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker

Product Description
LW-252 self-energy sulfur hexafluoride circuit breaker is outdoor AC three-pole 50Hz high-voltage power transmission and transformation equipment, used to split rated current, fault current or conversion line, to achieve the protection, control and operation of the power transmission system, can be opened, closed and fast automatic reclosing operation and three-pole electrical linkage.
The circuit breaker adopts the latest design principle, has the characteristics of simple structure, small volume, less consumables, small operation energy, high reliability, easy installation and low noise.
Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
Service Environment

1. Outdoor;
2. Ambient air temperature :-30ºC~+50ºC;
3. Altitude: does not exceed 3000m;
4. Relative humidity: the daily average is not more than 95%, the monthly average is not more than 90%;
5. The magnitude of the earthquake was no more than 9 degrees;
6. No fire, explosion, serious pollution, chemical corrosion and violent vibration.
7. Natural wind speed no more than 34m/s, wind pressure is no more than 700pa.

Product Parameters
No. Item Unit Data
1 Rated voltage KV


 
252
2 Rated power frequency withstand voltage (1min) 460
605
3 Rated lightning impulse withstand voltage  1050
1250
4 Power frequency under zero gauge pressure of SF6(5min) 220
5 Rated frequency Hz 50(60)
6 Rated current A 4000
7 First pole factor   1.3
8 Rated peak withstand current KA 100
9 Rated short-circuit breaking current 40
10 Rated pull-out breaking current 10
11 Rated short-time withstand current 40
12 Rated short-circuit CO current 100
13 Rated operational sequence   O-0.3s-CO-180s-CO
14 First pole factor   1.5
15 Opening time ms ≤34
16 Closing time 90-120
17 Main circuit resistance ≤50
18 Rated SF6 gas pressure (20ºC gauge pressure) MPa 0.40±0.015
19 Alarm/lowest function pressure (20ºC gauge pressure) 0.35±0.015/0.30±0.015
20 SF6 gas annual leakage percent   ≤1%
21 SF6 gas moisture content(V/V) u L/L ≤150
22 Mechanical life Time 6000 or 10000
23 SF6 gas weight Kg
 
8
24 Breaker weight 1700
 
 
Customer Case
Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
 
Packaging & Shipping
Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker
Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker

After-sales Service
1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.
2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.
3.We use quality authentic materials, process and manufacture in strict compliance with ISO9001:2000 international quality management to ensure the quality of excellence and the smooth installation!

Certifications
 

Three Pole AC Power System 252kv High Voltage Sf6 Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier