252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Manufacturer/Factory, Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • 252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
  • 252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
  • 252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
  • 252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
  • 252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
  • 252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Service Environment
  • Product Parameters
  • Product Features
  • Customer Case
  • Packaging & Shipping
  • Certifications
Overview

Basic Info.

Model NO.
LW43-252
Arc-extinguishing Medium
SF6
Installation
Fixed
Structure
ACB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CCC
Rated Voltage
252kv
Rated Current
4000A
Rated Frequency
50Hz
Customization
Acceptable
Language
Chinese, English, Russian
Protection Class
IP5xw
Loading Port
It Depends
Transport Package
Wooden Case or Others
Specification
Designed According to Supplier Specifications
Trademark
HZEC
Origin
China
Production Capacity
300000sets/Year

Product Description

Company Profile

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker

 

Product Description
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker

LW43-252 High voltage sulfur hexafluoride circuit breaker is a three-pole AC 50Hz outdoor high voltage switchgear. It is mainly used for the control and protection of 220kV power system, and can also be used as a contact circuit breaker.

Service Environment

1. Daily temperature difference: ≤25 ºC;
2. Sunshine: 0.1W /cm2;
3. Relative humidity: daily average ≤95%; Monthly average ≤90%
4. Wind speed: 34 m/s;
5. Earthquake resistance: horizontal acceleration 0.250g; Vertical acceleration 0.125g;
6. Pollution level: III (25mm/kV), IV (31mm/kV);
7. Ice thickness: 10 mm (wind speed is not more than 15m/s);
8. Protection level: IP5XW.

Product Parameters
No. Name   Unit   Parameters
Altitude     m 1000  2000 
Temperature   - -30ºC~40ºC -40ºC~40ºC -30ºC~40ºC -40ºC~40ºC
Rated voltage     kV 252 
Rated frequency     Hz 50 
Rated current     A 4000
Rated short-circuit breaking current, Isc     kA 50 40    50   40
Rated short-circuit closing current (peak)     kA 125 100  125   100
8
9
10
11
12
13
Rated short-time withstand current (valid value)     kA 50 40    50   40
Rated short-circuit lasting time   S 3 3    3
Rated peak withstand current     kA 125 100 125    100
Close-in fault breaking current     kA  bsc 90%, sc75%
Rated out-of-phase breaking current     kA  lsc 25%
14  First Breakover Coefficient   - 1.5 
15  Rated line-charging switching current     A 160
No-load transformer breaking current     A 0.5-20
16  1min Power frequency withstand voltage (valid value) Fracture   kV 460;395+145 460     460    460 
Pole-to-pole/grounding 460 460     460    460 
17  Lightning impulse withstand voltage (peak) Fracture   kV 1050;950+206 1050     1050   1050 
Pole-to-pole/grounding 1050 1050     1050    1050 
18  Rated operational sequence   -  0-0.3s-C0-180s-CO
19  Opening,closing operation voltage     V DC220; 110
20  Tripping coil current     A   2.0; 5.5
21  Closing coil current     A   2.0; 3.3
22  Motor current     V DC220(AC220)
23  Total breaking time     ms ≤60.0 
24  Tripping time     ms 24.0-35.0
25
26
27
Closing time
Close-open time
    ms
  ms
75.0-110.0
   60.0-70.0
28
29
Open-close time      ms
   ms
   300.0 
Opening synchronization     ms ≤4.0
30  Closing synchronization     ms ≤3.0
31  Travel     ms   120.0    ±2.0
              -5.0
Contacting travel   45.0      2.0
32 
SF6 Gas pressure
(20ºC)
Rated pressure
Alarm pressure
MPa 0.60
0.55
0.60
0.35
0.60
0.55
  0.60
  0.35
Blocking pressure 0.50  0.30  0.50    0.30 
33  SF6 Gas annual leakage ratio     % ≤0.5
34  Gas moisture content Acceptance value  ppm(v/v)    ≤150
Operation value    ≤300
35  Main loop resistance   μ Q    ≤55.0
36  Radio interference level     μV <500
37  Mechanical life     Time 3000 
38  Electrical life     Time 16 
39
40
Gas weight in each SF6   kg 16                 20                   16                  20
Weight of each circuit breaker     kg 4000 
Product Features

1. Strong self-extinguishing arc breaking ability;
2. Simple structure;
3. Use lengthened spout and materials to add new fillers;
4. Long electrical life;
5. Strong carrying capacity;
6. Good insulation performance;
7. Reliable sealing structure;
8. Low radio interference voltage;
9. Low noise operation;
10. There is no oil leakage or gas leakage;
11. Easy to install on site;
12. Less operation and maintenance.

252kv High Voltage Tripolar AC 50Hz Sf6 Circuit BreakerNote:
1. Weight: 4000kg(with gas);
2. Total gas weight: 35kg.
2. Base load: static 4000kg (three poles);
                               1333kg (per pole)
    Dynamic horizontal direction F: 2200kg;
    Vertical direction (upward) : 3000kg;
    Vertical direction (downward) : 5000kg.
3. The levelness of the concrete surface is not more than 1.5mm.
4. The mounting hole for connecting the wiring terminal with the primary line shall be drilled according to the needs of the user on site.
The terminal material is aluminum alloy 2A12-T4.

Customer Case

 

252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker


 
Packaging & Shipping
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker
252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker

After-sales Service
1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.

2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.

3.We use quality authentic materials, process and manufacture in strict compliance with ISO9001:2000 international quality management to ensure the quality of excellence and the smooth installation!
 

Certifications
 
 

252kv High Voltage Tripolar AC 50Hz Sf6 Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier