Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Manufacturer/Factory, Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
  • Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
  • Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
  • Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
  • Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
  • Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Product Parameters
  • Service Environment
  • Outline Diagram Examples
  • Packaging & Shipping
  • FAQ
  • Certifications
Overview

Basic Info.

Model NO.
FN21-12
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
Lbs
Poles Number
3
Type
Fn21-12
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
CCC
Currency
RMB or USD
Language
Chinese, English, Russian
Loading Port
It Depends
Frequency
50Hz
Rated Voltage
12kv
Rated Current
630A
Mechanism Type
Manual
Transport Package
Standarded Export Case
Specification
As required
Trademark
HZEC
Origin
China
Production Capacity
3000 Sets/Month

Product Description

Company Profile

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
Product Description
FZN21-12D/T630-20\FZRN21-12D/T125-31.5 type high voltage vacuum load switch and combined electrical appliances for three-phase AC 12KV, 50Hz power distribution system, with compact structure, small size, light weight, long life, closing and breaking ability strong safety and reliability, etc. Combined with fuses (referred to as combined appliances), can replace the cost of higher circuit breakers, its operation and maintenance is simple and convenient.
Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
 
Product Parameters
No. Item
 
Unit
 
Data
FZN21 FZRN21
1 Rated voltage KV 12 12
2 Rated current A 630 125
3 Rated short-circuit opening current KA 50 50
4 Rated short-circuit breaking current  KA - 31.5
5 Rated active load breaking current A 630 630
6 4S Thermal stable current KA 30 -
7 Dynamic stable current KA 50 -
8 1min power frequency withstand voltage KV 43(fracture 48) 42(fracture 48)
9 Lightning impulse withstand voltage KV 75(fracture 85) 75(fracture 85)
10 Mechnical life Time 10000 10000
11 Rated transfer current A - 3150
12 Operating power voltage V AC DC 110,220 AC DC 110,220
 
Service Environment
1. Altitude: ≤1000m;
2. Ambient temperature: -25ºC~+40ºC;
3. Relative humidity: the daily average is not more than 95%, the monthly average is not more than 90%;
4. No conductive dust, corrosive gases and water vapor;
5. No fire and explosive risk;
6. No violent vibration, tilt less than 3°.   
Outline Diagram Examples
Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
1. Frame   2. Spacer knife   3.Fuse   4. Insulating tie rod   5. Upper bracket  6. Arc suppressing chamber
7. Ground knife static contact  8. Insulator   9. Grounding switch   10. Ground spring
11. Opening spring   12. Insulating tie rod    13. Principal axis     14. Trip mechanism
15. Countershaft   16. Linkage link     17. Operating mechanism                                                                                   
Packaging & Shipping
Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse
 
FAQ

Q: Could I have prices of your products?
A: Welcome. Please feel free to send us inquiry here. We will reply you within 24 hours.

Q: Can we print our logo/ company name on products?
A: Yes, of course, we accept OEM, then need you to provide brand authorization to us.

Q:Do you accept product customization?
A:Yes, of course, please provide specific drawings or parameters, we will quote you after evaluation.

Q: What is the lead time? 
A: The lead time depends on the quantities ordered, generally within 7-20 days after receiving the payment. 

Q: What is your Trade Terms? 
A: We accept EXW, FOB, CIF, FCA, etc. 

Q: Do you inspect the finished products?
A: Yes, each step of production and finished products will be came out inspection by QC department before shipping. And we will provide goods inspection reports for your reference before shipment

Q: How to solve the quality problems after sales? 
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days.

Certifications

Three-Phase AC Power Distribution System Indoor High-Voltage Vacuum Load Switch Fuse

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier