220kv Double-Winding Power Transformers with off-Circuit Tap Changer

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Three
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (11)
  • 220kv Double-Winding Power Transformers with off-Circuit Tap Changer
  • 220kv Double-Winding Power Transformers with off-Circuit Tap Changer
  • 220kv Double-Winding Power Transformers with off-Circuit Tap Changer
  • 220kv Double-Winding Power Transformers with off-Circuit Tap Changer
  • 220kv Double-Winding Power Transformers with off-Circuit Tap Changer
  • 220kv Double-Winding Power Transformers with off-Circuit Tap Changer
Find Similar Products
  • Overview
  • Product Description
  • Main Features
  • Product Details
  • Product Parameters
  • Product Display
  • Fields of application
  • Customer Case
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
SSZ11-240000/220
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001, CCC
Usage
Power Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Transport Package
According to Client′ S
Specification
As manufacturer′ s design
Trademark
HZEC
Origin
China
HS Code
8504232100
Production Capacity
25/ Quarter

Product Description

Product Description
220kV Power Transformer The 220kV transformer is a high-voltage oil-immersed transformer with a core-type structure. It can be classified by phase number into single-phase transformers and three-phase transformers; by voltage regulation method into on-load tap-changing transformers and no-load tap-changing transformers; by winding coupling method into power transformers and autotransformers; by the number of windings into double-winding, three-winding, and three-winding plus balance winding transformers. Additionally, it includes special types such as split transformers and combined transformers. The product is designed according to IEC international standards, IEEE standards, and current national standards.
220kv Double-Winding Power Transformers with off-Circuit Tap Changer

 

Main Features

Low Noise: Reduces noise pollution to the environment.

Low Partial Discharge: Ensures stable and reliable transformer operation.
Low Temperature Rise: Provides strong overload capacity.
Low Loss: Optimizes energy structure.
Leakage-Free: Ensures high sealing performance of the transformer.
Maintenance-Free: Reduces customer maintenance costs.
High Impedance: Offers high short-circuit resistance, providing transformer safety.
Smart Components: Incorporates intelligent substation design technolog .

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable transformer manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations and high and low voltage complete sets of equipment.The equipment put into production and operation of the project advocates energy saving, intelligence, information and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center,with 71 utility model patents and 15 invention patents.With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC Products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa and other regions, covering more than 40 countries.
220kv Double-Winding Power Transformers with off-Circuit Tap Changer

 

Product Details


220kv Double-Winding Power Transformers with off-Circuit Tap ChangerTheir main features include:

1. Low noise, reducing noise pollution to the environment;
2. Low partial discharge, ensuring stable and reliable operation of the transformer;
3. Low temperature rise, with strong overloading capacity;
4. Low loss, optimizing the energy structure;
5. No leakage, with high sealing performance of the transformer;
6. Maintenance-free, reducing the customer's maintenance costs;
7. High impedance, with high short-circuit resistance, enhancing the safety performance of the transformer;
8. Utilization of intelligent components, incorporating intelligent power station design technology.

Product Parameters

 

220kV Double-winding Power Transformers with Off-circuit Tap Changer

Rated capacity
(kVA)
  
Voltage ratio andtap range
           (kV)

Connection
Symbol

No-load loss
(kW)

Full-load loss
(kW)

Impedance
(%)

No-load current
(%)
   HV       LV
31500        220
  242±2x2.5%
   6.3
   6.6
   10.5
   11
YNd11 35  135  12~14 0.70 
40000  41  157  0.70 
50000  49  189  0.65 
63000  58  220  0.65 
75000     10.5
   11
   13.8
67  250  0.60 
90000  77  288  0.55 
120000  94  345  0.55 
150000  11;13.8;
15.75;20
112  405  0.50 
180000  128  459  0.46 
240000  160  567  0.42 
300000   15.75;
 18;20
189  675  0.38 
360000  217  774  0.38 

220kVDouble-winding Power Transformers with Off-circuit TapChanger With 66kV of Low Voltage

Rated capacity
(kVA)

Voltage ratio and tap range
(kV)

Connection
Symbol

No-load loss
(kW)

Full-load loss
(kW)

Impedance
(%)

No-load current
(%)
   HV    LV
31500    220±2x2.5% 63
66
69
YNd11 38  151  12~14 0.89 
40000  45  176  0.89 
50000  53  211  0.82 
63000  63  247  0.82 
90000  83  323  0.75 
120000  102  387  0.75 
150000  122  453  0.68 
180000  138  513  0.68 
240000  171  635  0.61 

220kV Double-winding Power Transformers with On-load Tap-changer

Rated capacity
(kVA)
Voltage ratio and tap range
(kV)

Connection
Symbol

No-load loss
(kW)

Full-load loss
(kW)

Impedance
(%)

No-load current
(%)
HV  LV
31500  220±8x1.25%   66.3;6.6
  10.5;11
   35;37;38.5
YNd11 38  135  12~14 0.70 
40000  45  157  0.63 
50000  54  189  0.56 
63000  63  220  0.56 
90000  10.5;11

35;37;38.5
80  288  0.49 
120000  99  346  0.49 
150000  116  405  0.42 
180000  135  468  0.42 
120000   66
69
102  355  0.49 
150000  120  415  0.42 
180000  140  475  0.42 

220kV Three-winding Power Transformers with Off-circuit Tap Changer


Rated capacity
(kVA)

    
Voltage ratio and tap range
          (kV)
            
HV         MV        LV


Connection
Symbol


No-load loss
(kW)


Full-load loss
(kW)

     
     Impedance
        (%)
    
step-up      step-down


No-load current
(%)
31500  220
242±2

X
2.5%
69

115
121
 6.3
 6.610.5
 11
 3537
 38.5
YNyn0d11 40  162 

H-M

22~24


H-L
12~14


M-L

7~9


H-L

22~24

H-M
12~14


M-L

7~9
0.70 
40000  48  189  0.63 
50000  56  225  0.56 
63000  66  261  0.56 
90000   10.511
 13.835
 3738.5
86  351  0.49 
120000  106  432  0.49 
150000   1113.8
 15.75
 3537
 38.5
125  513  0.42 
180000  142  585  0.42 
240000  176  720  0.35 
300000  208  750  0.30 

220kV Three-winding Auto-transformers with Off-circuit Tap Changer
Rated capacity
(kVA)
Voltage ratio and tap range
(kV)
Connection
Symbol
No-load loss
(kW)
  Full-load loss
    (kW)
Impedance
(%)
No-load current
(%)
HV MV LV   step-up step-down step-up step-down   step-up step-down
31500       6.6
 10.5
11
35
37
  38.5 
YNyn0d11   25  22  117  99   
H-M

H-M
0.50 
40000    29  26  144  121  0.50 
50000  220      34  30  170  144    12~14 8~10 0.43 
63000  242±2 115    40  36  201  171    H-L H-L 0.43 
90000  X 121    50  46  276  234  0.36 
120000  2.5%   10.5
11
13.8
15.75
18
35
37
38.5
  02  56  340  288    8~12 28~34 0.36 
150000        70  60  405  342   
M-L

M-L
0.33 
180000        80  72  464  387  0.33 
240000        95  86  595  504    14~18  18~24 0.25 

 220kV Three-winding Power Transformers with On-load Tap-changer


Rated capacity
(kVA)

  
  Voltage ratio and tap range
          (kV)
     
HV        MV         LV


Connection
Symbol


No-load loss
(kW)


Full-load loss
(kW)


Impedance
(%)


No-load current
(%)
31500  220

±8

X
1.25%
69
115

121

6.3 6.6
10.511
35
37
38.5
YNyn0d11 44  162 
H-L
22~24

H-M
12~14


M-L
7~9
0.77 
40000  52  189  0.70 
50000  60  225  0.63 
63000  70  261  0.63 
90000  10.5
11
35
37
38.5
92  351  0.56 
120000  115  432  0.56 
150000  135  513  0.49 
180000  159  630  0.49 
240000  193  780  0.45 

220kV Three-winding Auto-transformers with On-load Tap-changer

Rated capacity
(kVA)

  
  Voltage ratio and tap range
          (kV)

HV         MV         LV


Connection
Symbol


No-load loss
(kW)


Full-load loss
(kW)


Impedance
(%)


No-load current
(%)
31500  220

±8

X
1.25%
115

121
6.3
6.610.5
11
35
37
38.5
YNyn0d11 25  108 

H-L

28~34

H-M
8~10

M-L


18~24
0.56 
40000  30  132  0.56 
50000  36  157  0.49 
63000  42  189  0.49 
90000  51  247  0.42 
120000  10.5
11
00
37
38.5
64  308  0.42 
150000  76  365  0.35 
180000  85  419  0.35 
240000  104  540  0.30 
 
Product Display

220kv Double-Winding Power Transformers with off-Circuit Tap Changer
Service environment
1.Device types: outdoor type

2.Type of Voltage Regulation: Off-circuit or On-Ioad
3.Tapping Range: ±5 % ±2x2.5 % ±4x2.5 %
4.Frequency: 50Hz or 60Hz
5.Phases: Three or single
6.Connection Symbol: Dyn11,Yyn0 ( or as requested)
7.Short- circuit Impedance: Standard Impedance
8.Altiude is not exceeding 1000m,ambient temperature not exceeding 40OC. If it can't meet such conditions,we will modulate parameters in accordance with standard.

Fields of application

 

220kv Double-Winding Power Transformers with off-Circuit Tap Changer
Customer Case

220kv Double-Winding Power Transformers with off-Circuit Tap Changer

After-sales service
1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.

2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.

3.We use quality authentic materials, process and manufacture in strict compliance with ISO9001:2000 international quality management to ensure the quality of excellence and the smooth installation!
 

Packaging & Shipping

220kv Double-Winding Power Transformers with off-Circuit Tap Changer220kv Double-Winding Power Transformers with off-Circuit Tap Changer


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier